Assessment of Simulation Modelling and Real-Time Measurements for 3.15 and 17.28 kWp Solar Photovoltaic (PV) Systems in Malaysia

Banupriya Balasubramanian, Azrul Mohd Ariffin, Samer Husam Al-Zubaidi

Abstract


The aim of this research work is to develop a portable simulation system that can measure ambient temperature (Ta) and solar irradiance (G) in real time, and then compute the energy that can be generated from a pre-defined PV system using these measurement data via a built-in graphic user interface (GUI). In constructing this system, a simulation modelling of PV output based on cell temperature and solar irradiance has been developed. The model was based on the first principles of representing a solar module with an equivalent circuit that takes into account the cell temperature, solar irradiance and all other parameters related to the cell. The accuracy of this simulation system was then being validated using the solar panel manufacturer’s datasheet and also two PV systems that are available; 3.15 kWp solar PV rooftop system and 17.28 kWp solar PV carport system. Good agreements have been found between the simulated results and the measured field data. The developed simulation system can be potentially used in forecasting the power output generated by a solar module at a specific location without the need for actual installation.

Keywords


Portable simulation system; Graphic user interface; UNITEN; Solar PV rooftop system; Simulation modelling; Cell temperature

Full Text:

PDF

References


Arati Kane, and Dr.Vishal Verma, “Performance Enhancement of Building Integrated Photovoltaic Module using Thermoelectric Coolingâ€, International Journal of Renewable Energy Research, vol. 3, pp. 320-324, April 2013.

F. Sarhaddi, S. Farahat, H. Ajam, and A. Behzadmehr, “Exergetic Performance Evaluation of a Solar Photovoltaic (PV) Arrayâ€, Australian Journal of Basic and Applied Sciences, vol. 4, pp. 502-519, March 2010.

Mukesh Kumar Gupta, and Rohit Jain, “MPPT Simulation with DC Submersible Solar Pump using Output Sensing Direct Control Method and Cuk Converterâ€, International Journal of Renewable Energy Research, vol. 3, pp. 186-191, March 2013.

A. Ibrahim, M. R. I. Ramadan, A. A. El-Sebaii, and S. M. El-Broullesy, “Annual Performance of Solar Modules with Tilting Angle Facing South and Sun Tracking in Tanta, Egyptâ€, International Journal of Renewable Energy Research, vol. 1, pp. 26-40, May 2011.

Rustu Eke, and Sener Oktik, “Seasonal Variation of Internal Parameters of Amorphous Silicon (a-Si) Thin Film Photovoltaic Modulesâ€, International Journal of Renewable Energy Research, vol. 2, pp. 549-555, August 2012.

VandanaKhanna, Bijoy Kishore Das, and Dinesh Bisht, “MATLAB/SIMELECTRONICS Models Based Study of Solar Cellsâ€, International Journal of Renewable Energy Research, vol. 3, pp. 30-34, December 2012.

R. G. Ross, and M. I. Smokler, “Electricity from photovoltaic solar cells: Flat-Plate Solar Array Project final report. Volume VI: Engineering sciences and reliabilityâ€, JPL Publication, pp. 86-31, October 1986.

A. Ghouari, Ch. Hamouda, A. Chaghi, and M. Chahdi, “Data monitoring and performance analysis of a 1.6kWp grid connected PV system in Algeriaâ€, International Journal of Renewable Energy Research, vol. 6, pp. 34-42, December 2015.

Sadok Mohammed, Benyoucef Boumediene, and Benmedjahed Miloud, “Assessment of PV Modules Degradation based on Performances and Visual Inspection in Algerian Saharaâ€, International Journal of Renewable Energy Research, vol. 6, pp. 106-116, January 2016.

Luis Castaner, and Santiago Silvestre, Modelling Photovoltaic Systems Using PSpice, England: John Wiley & Sons Ltd, 2002.

Raam Perumal, “Loss Due to Ambient Temperatureâ€, PVSyst Manual, 2011.

Marilyn Walker, “How HOMER Calculates the PV Cell Temperature?†Retrieved from http://support.homerenergy.com/index.php?/Knowledgebase/Article/View/489/0/10487---how-homer-calculates-the-pv-cell-temperature, 2012. [Accessed: Jul. 15, 2014]

Suresh A/L Thanakodi, “Modeling and simulation of grid connected photovoltaic system using Matlab / Simulinkâ€, Master’s thesis, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia, November 2009.

PVEducation, “Nominal Operating Cell Temperatureâ€, [Online] 2013. Available from: http://pveducation.org/. [Accessed: Nov. 09, 2013]

Carrero, J. Amador, and S. Arnaltes, “A Single Procedure for Helping PV Designers to Select Silicon PV Module and Evaluate the Loss Resistances†Renewable Energy, vol. 32, pp. 2579-2589, December 2007.

Andreas Wagner, “Peak-Power and Internal Series Resistance Measurement under Natural Ambient Conditionsâ€, EuroSun Copenhagen, June, 2000.

Altas I. H., and Sharaf A. M, “A Photovoltaic Array Simulation Model for Matlab-Simulink GUI Environmentâ€, International Conference on Clean Electrical Power (ICCEP ‘07), pp. 341-345, May 2007.

Ramos Hernanz J. A., Campayo Martin J. J., Zamora Belver I., Larranaga Lesaka J., Zulueta Guerrero E., and Puelles Perez E, “Modelling of Photovoltaic Moduleâ€, International Conference on Renewable Energies and Power Quality (ICREPQ’10), March 2010.

J. A. Gow, and C. D. Manning, “Development of a photovoltaic array model for use in power-electronics simulation studiesâ€, IEE Proceedings-Electric Power Applications, vol. 146, pp. 193-200, 1999.

A. Ibrahim, and A. A. El-Amin, “Temperature Effect on the Performance of of n-Type uc -Si Film Grown by Linear Facing Target Sputtering for Thin Film Silicon Photovoltaic Devicesâ€, International Journal of Renewable Energy Research, vol. 2, pp. 160-165, February 2012.

André Coelho, and Rui Castro, “Sun Tracking PV Power Plants: Experimental Validation of Irradiance and Power Output Prediction Modelsâ€, International Journal of Renewable Energy Research, vol. 2, pp. 23-32, October 2011.

Ahmad Hadri Haris, “Grid-connected and Building Integrated Photovoltaic: Application Status & Prospect for Malaysiaâ€, MBIPV Project, PTM (Malaysia Energy Centre), 2006.

Siemens / Shell SP-75 Module Technical Datasheet. Retrieved from http://www.solardirect.com/PDF/SolarElectric/sp75.pdf

Q-Cells 240 Wp Module Technical Datasheet. Retrieved from http://www.q-cells.com/uploads/tx_abdownloads/files/Q-Cells_QBASE-G2_Data_sheet_2011-06_Rev02.pdf

Hedzlin Zainuddin., Sulaiman Shaari., Ahmad Maliki Omar., and Shahril Irwan Sulaiman, “Power Prediction for Grid-Connected Photovoltaic System in Malaysiaâ€, 3rd International Symposium & Exhibition in Sustainable Energy & Environment, pp. 110-113, August 2011.

Ahmad, V. Tan, W. N. Chen, and D. Ruoss, “11.88 kWp BIPV System Installation at Putrajaya Perdana Berhad HQ, P16, Putrajayaâ€, Malaysia Building Integrated Photovoltaic (MBIPV) Project, 2007. Retrieved from http://www.mbipv.net.my/dload/MBIPV%20Reports/C2/Putrajaya%20Perdana%20Bhd.pdf

Ahmad, V. Tan, W. N. Chen, and D. Ruoss, “4.2 kWp BIPV System Installation at No 96, Lot 5650, Lorong Indah 2, Taman Perkota, Bukit Sebukor Melakaâ€, Malaysia Building Integrated Photovoltaic (MBIPV) Project, 2007. Retrieved from http://www.mbipv.net.my/dload/MBIPV%20Reports/C2/Bt%20Sebukor%20Melaka.pdf

Ahmad, V. Tan, W. N. Chen, and D. Ruoss, “4.0 kWp BIPV System Installation at Lot 488, Jalan Khaya, Country Heights Damansara, Petaling Jayaâ€, Malaysia Building Integrated Photovoltaic (MBIPV) Project, 2007. Retrieved from http://www.mbipv.net.my/dload/MBIPV%20Reports/C2/Damansara.pdf

Ahmad, V. Tan, W. N. Chen, and D. Ruoss, “9.9 kWp BIPV System Installation at Damansara Utama Shoplots, Damansara Utamaâ€, Malaysia Building Integrated Photovoltaic (MBIPV) Project, 2007. Retrieved from http://www.mbipv.net.my/dload/MBIPV%20Reports/C2/Damansara%20Utama%20shoplots.pdf




DOI (PDF): https://doi.org/10.20508/ijrer.v7i1.5246.g6978

Refbacks

  • There are currently no refbacks.


Online ISSN: 1309-0127

Publisher: Gazi University

IJRER is cited in SCOPUS, EBSCO, WEB of SCIENCE (Clarivate Analytics);

IJRER has been cited in Emerging Sources Citation Index from 2016 in web of science.

WEB of SCIENCE between 2020-2022; 

h=30,

Average citation per item=5.73

Impact Factor=(1638+1731+1808)/(189+170+221)=9.24

Category Quartile:Q4